Interface PLC and the electrical circuit is output through the input section (I / O) to complete. plc IO module integrates the PLC's I / O circuit, the input register reflecting the input signal, the output point to reflect the state of the output latch. Input module into the electric signal into a digital signal the PLC system, the opposite output module. I / O into the digital input (DI), switching plc analog input output module, the analog input (AI), analog output (AO) modules.
LC switch output roughly divided into three types, relay output, transistor output type and triac output type. AC to DC relay outputs are transistor common with 5VDC and 24VDC output, SCR is relatively rare, and only special output models only. Considering the selection of the output module type.
2015年8月9日星期日
2015年8月1日星期六
Programmable Logic Controller (PLC) hardware measures:
The main modules are used large-scale or large scale integrated circuits, a large number of switching operations performed by non-contact electronic memory, plc IO module system design have improved the channel protection and signal conditioning circuit.
① shield - to power transformers, CPU, programmers and other major components, the use of electrical conductivity, magnetic shielding material good, to prevent outside interference.
② filter - the power supply system and an input line filter in various forms, such as intelligent plc or π-type filter network to eliminate or suppress high frequency interference, but also weakened the interaction between the various modules.
③ power adjustment and protection - the core components of the microprocessor needed a + 5V supply, the use of multi-stage filter and make adjustments with the integrated voltage regulator to adapt to fluctuations in the exchange and over-grid voltage, under influence of voltage.
④ isolation - between the microprocessor and I / O circuits, opto-isolated, effectively isolate the electrical connection between the I / O interface with the CPU contact, reducing failures and malfunctions; between the I / O port also isolated from each other.
⑤ with modular structure - This structure helps in case of failure to repair short. Once identified a faulty module can easily be replaced quickly, allowing the system to resume normal work; also helps to accelerate find the cause of the fault.
① shield - to power transformers, CPU, programmers and other major components, the use of electrical conductivity, magnetic shielding material good, to prevent outside interference.
② filter - the power supply system and an input line filter in various forms, such as intelligent plc or π-type filter network to eliminate or suppress high frequency interference, but also weakened the interaction between the various modules.
③ power adjustment and protection - the core components of the microprocessor needed a + 5V supply, the use of multi-stage filter and make adjustments with the integrated voltage regulator to adapt to fluctuations in the exchange and over-grid voltage, under influence of voltage.
④ isolation - between the microprocessor and I / O circuits, opto-isolated, effectively isolate the electrical connection between the I / O interface with the CPU contact, reducing failures and malfunctions; between the I / O port also isolated from each other.
⑤ with modular structure - This structure helps in case of failure to repair short. Once identified a faulty module can easily be replaced quickly, allowing the system to resume normal work; also helps to accelerate find the cause of the fault.