Interface PLC and the electrical circuit is output through the input section (IO) completed. plc IO module integrates the PLC IO circuit, the input registers reflect the state of the input signal, output point to reflect the state of the output latch. The input module signals into the electrical signals into digital PLC system, the opposite output module. IO into digital input (DI), switching output (DO), the analog input (AI), analog output module. Modular PLC including the cpu module, I / O modules, memory, power supply modules, backplane or rack, these modules can be configured according to certain rules of combination.
LC switch output roughly divided into three types, relay output, transistor output type and triac output type. AC to DC relay outputs are transistor common with 5VDC and 24VDC output, SCR is relatively rare, and only special output models only. Considering the selection of the output module type.
2015年10月18日星期日
2015年5月14日星期四
PLC analog output module with low cost expansion
Programmable controller (hereinafter referred to as PLC) due to the high reliability, simple programming, strong versatility, small size, compact structure, installation, plc analog output module maintenance is convenient wait for a characteristic, and in industrial control has been widely used. General PLC module for the following categories, switch quantity input module, switch module output, analog input module and analog output module.
In the industrial control especially process control in the field of analog acquisition and control needs to be more, more and need of PLC Analog input and output module, and analog input and output module is more expensive and increase the analog input and output module increases the cost and reduce the price of the entire system, limit the application of PLC. This paper presents a method of extended analog input output module, high-speed counter modules communication based on trying to solve this problem.
In the industrial control especially process control in the field of analog acquisition and control needs to be more, more and need of PLC Analog input and output module, and analog input and output module is more expensive and increase the analog input and output module increases the cost and reduce the price of the entire system, limit the application of PLC. This paper presents a method of extended analog input output module, high-speed counter modules communication based on trying to solve this problem.
2015年3月26日星期四
How to select plc IO module manufacturers
Domestic production plc IO module manufacturers are said to have many
thousands, how can choose their own power supply module manufacturers
do?
1, for the size of their own requirements. Some foreign brand quality is really good, but the price is not every user can programmable plc accept, plc IO module and delivery compared to domestic brands, is very long. For some of the larger domestic supplier of power modules also have this problem, if you set its main ship models of non-models, delivery is also not guaranteed. If you own custom made a special power, for small customers, is simply unthinkable. Because SMEs did not like Huawei, ZTE delivery platform choice, to choose their own scale enterprises, is very important. VST such as power companies, specifically for SMEs to provide power solutions, to provide customized services.
2, plc IO module product line to see the plc temperature control module situation. Such as power modules, it can provide as a half brick, 1/4 brick, 1/8 brick, 1/16 brick industrial products such as can not provide, explain corporate R & D strength and size is small. The ability to customize the product, whether it can provide a wealth of customized products, customized experience like railways, electricity, military areas or very important. Look material. Open a module power, their own look, workable than listen to others. Material from the supply of products, we can see that the quality of power supply manufacturers and positioning, choice of materials, like the Programmable Input Module power to see the materials. Open a module power, their own look, workable than listen to others. Material from the supply of products, we can see that the quality of power supply manufacturers and positioning, choice of materials like power
1, for the size of their own requirements. Some foreign brand quality is really good, but the price is not every user can programmable plc accept, plc IO module and delivery compared to domestic brands, is very long. For some of the larger domestic supplier of power modules also have this problem, if you set its main ship models of non-models, delivery is also not guaranteed. If you own custom made a special power, for small customers, is simply unthinkable. Because SMEs did not like Huawei, ZTE delivery platform choice, to choose their own scale enterprises, is very important. VST such as power companies, specifically for SMEs to provide power solutions, to provide customized services.
2, plc IO module product line to see the plc temperature control module situation. Such as power modules, it can provide as a half brick, 1/4 brick, 1/8 brick, 1/16 brick industrial products such as can not provide, explain corporate R & D strength and size is small. The ability to customize the product, whether it can provide a wealth of customized products, customized experience like railways, electricity, military areas or very important. Look material. Open a module power, their own look, workable than listen to others. Material from the supply of products, we can see that the quality of power supply manufacturers and positioning, choice of materials, like the Programmable Input Module power to see the materials. Open a module power, their own look, workable than listen to others. Material from the supply of products, we can see that the quality of power supply manufacturers and positioning, choice of materials like power
2015年3月19日星期四
input module plc introduced in the DC chopper
DC / DC converter is a variable DC voltage into a fixed DC voltage ,
also known as a DC chopper . Chopper work in two ways , first pulse
width modulation Ts constant change ton ( GM ), input module plc Second,
frequency modulation (
(1) Buck circuit - step-down intelligent plc chopper , the output average voltage less than the input voltage U0 Ui, of the same polarity .
(2) Boost Circuit - boost chopper , the output voltage U0 is greater than the average input voltage Ui, the same polarity .
(3) Buck-Boost circuit - a buck or boost chopper , the average output voltage is greater or less than the input voltage U0 Ui, of opposite polarity , inductive transmission. 4) Cuk circuit - a buck or boost chopper , the average output voltage is greater or less than the input programmable logical controllers voltage U0 Ui, of opposite polarity , capacitance of the transmission . There Sepic, Zeta circuits. input module plc above non-isolated DC-DC converter circuit , isolated DC-DC converter circuit has a forward , flyback , half-bridge circuit , full bridge circuit , push-pull circuit .
Soft-switching technology makes plc intelligent controller today's DC / DC undergone a qualitative leap , the maximum output power 300W, 600W, 800W , etc. , the corresponding power density (6.2,10,17) W/cm3, efficiency ( 80 to 90 ) % . The switching frequency (200 ~ 300) kHz, the power density has reached 27W/cm3.
(1) Buck circuit - step-down intelligent plc chopper , the output average voltage less than the input voltage U0 Ui, of the same polarity .
(2) Boost Circuit - boost chopper , the output voltage U0 is greater than the average input voltage Ui, the same polarity .
(3) Buck-Boost circuit - a buck or boost chopper , the average output voltage is greater or less than the input voltage U0 Ui, of opposite polarity , inductive transmission. 4) Cuk circuit - a buck or boost chopper , the average output voltage is greater or less than the input programmable logical controllers voltage U0 Ui, of opposite polarity , capacitance of the transmission . There Sepic, Zeta circuits. input module plc above non-isolated DC-DC converter circuit , isolated DC-DC converter circuit has a forward , flyback , half-bridge circuit , full bridge circuit , push-pull circuit .
Soft-switching technology makes plc intelligent controller today's DC / DC undergone a qualitative leap , the maximum output power 300W, 600W, 800W , etc. , the corresponding power density (6.2,10,17) W/cm3, efficiency ( 80 to 90 ) % . The switching frequency (200 ~ 300) kHz, the power density has reached 27W/cm3.
2015年3月12日星期四
Enter the installation of wiring module plc
input module plc end if set to "always check line" status input module input end of the line (away from
the module side) must be parallel with the termination resistor programmable logic controller (plc) suppli
ers module inputs If set to "normally closed check line" Status Input Module Input end of the line (a
way from the module side) must be a plc analog output module in series termination resistors. When th
module is active output, active output terminal should be parallel termination resistor 4.7kΩ, and IN40
07 series with a diode.
2015年3月9日星期一
Selection of low-cost analysis of the input module plc
PLC because of its high reliability , simple programming ,
versatility , small size, compact structure, convenient installation and
maintenance , etc. , and in the industrial control has been widely used
. PLC modules are generally divided into the following categories :
switch input modules , digital output modules , analog input module ,
analog output modules. Industrial plc digital input output module control,
especially in the field of process control and control need to collect
more than analog , input module plc thus PLC analog input and output
modules require more, and analog input and output modules are more
expensive, increase the analog input and output modules increases the
cost and reduces the cost of the entire system , input module plc limit
the application of PLC. This paper presents a communication -based
analog input and output modules extension method seeks to solve this
problem based Programmable Input Module on analog communication input, output module extension methods
PLC analog input module 12 extend all the way to where the analog input , for example, in the form of an analog signal standard 0 ~ 5V input voltage signal feeding side, the application 12 A / D conversion chip MAX187 analog- digital conversion. MAX187 is a 12-bit serial A / D, has a high conversion rate , the sampling frequency is 75kHz, suitable for high precision here all the way 12-bit analog output , for example, the design will be plc intelligent controller using 12 D / A converter chip MAX531 to achieve the number of touch conversion. We MAX531 op amp output termination , the analog output is adjusted to 0 ~ 5V, the output part of the hardware circuit shown in Figure 3 . Here , MAX531 is a 12-bit serial D / A, has a higher conversion rate...
PLC analog input module 12 extend all the way to where the analog input , for example, in the form of an analog signal standard 0 ~ 5V input voltage signal feeding side, the application 12 A / D conversion chip MAX187 analog- digital conversion. MAX187 is a 12-bit serial A / D, has a high conversion rate , the sampling frequency is 75kHz, suitable for high precision here all the way 12-bit analog output , for example, the design will be plc intelligent controller using 12 D / A converter chip MAX531 to achieve the number of touch conversion. We MAX531 op amp output termination , the analog output is adjusted to 0 ~ 5V, the output part of the hardware circuit shown in Figure 3 . Here , MAX531 is a 12-bit serial D / A, has a higher conversion rate...
2015年3月5日星期四
Some of the sequence output module plc
An automatic identification IO modules, IO consecutive numbers down
by a physical connection. But the program even without the IO module may
still running down. Because IO address is mapped to the cpu's memory,
program memory operations generally.
2 software configuration and download it to the cpu to identify the IO module. Once the module occurs from such failure, cpu system plc communication modules fault alarm can be issued immediately, the hardware must meet the configuration settings, and IO address mapping can also be freely allocated memory space.
I / O expansion bus, there are many, output module plc various PLC manufacturers are different, or look at the refresh rate. Slow, then you can use SPI and the like, and then a little faster, then you can do a physical interface with FPGA, there is one of the fastest Industrial Ethernet.
Simple application can even use the serial port to do. I / O port expansion is the I / O address to the CPU memory map, but plc logic controller this map is a combination of software and hardware self-identification are defined manually or through assignment and allocation. May be in the exhaust line is whether there should be a line behind the front of the module has a successor in charge of the report module, if the module behind the successor state that level on this line, and when no module is not the same, so that they can be judged No follow-up module, CPU module communicates with other modules using the relay mode, the transmission down a level, that is, only the CPU module and from his recent communication module, output module plc and other modules if you want Communication would have to transit through plc controller manufacturer other modules, so that modules are installed in accordance with the order of the address of the module can be determined, on power CPU perform a self-test program, each module to report their labeling information so that you can know the total CPU module the number of mounted modules, each module location and type of each module.
2 software configuration and download it to the cpu to identify the IO module. Once the module occurs from such failure, cpu system plc communication modules fault alarm can be issued immediately, the hardware must meet the configuration settings, and IO address mapping can also be freely allocated memory space.
I / O expansion bus, there are many, output module plc various PLC manufacturers are different, or look at the refresh rate. Slow, then you can use SPI and the like, and then a little faster, then you can do a physical interface with FPGA, there is one of the fastest Industrial Ethernet.
Simple application can even use the serial port to do. I / O port expansion is the I / O address to the CPU memory map, but plc logic controller this map is a combination of software and hardware self-identification are defined manually or through assignment and allocation. May be in the exhaust line is whether there should be a line behind the front of the module has a successor in charge of the report module, if the module behind the successor state that level on this line, and when no module is not the same, so that they can be judged No follow-up module, CPU module communicates with other modules using the relay mode, the transmission down a level, that is, only the CPU module and from his recent communication module, output module plc and other modules if you want Communication would have to transit through plc controller manufacturer other modules, so that modules are installed in accordance with the order of the address of the module can be determined, on power CPU perform a self-test program, each module to report their labeling information so that you can know the total CPU module the number of mounted modules, each module location and type of each module.
output module plc connect to 4G network test
In the end how fast network speeds of 4G? Prior to this, have
repeatedly reported that several times faster than 3G networks to 4G,
output module plc only a few minutes to download several G movies, etc.
These plc digital input output module reports,
many of which are advertising in business, few real The person tested
and the test results posted for your reference. In Baidu Encyclopedia,
also known as 4G systems capable of speeds of 100Mbps download 2000
times faster than dial-up Internet access, upload speed can reach
20Mbps. At present, many of my friends like to watch videos online, I
also watch movies with China Mobile TD-LTE 4G network, watch the whole
video is industrial automation plc very
smooth, output module plc no obvious lag, the test results show that
the speed of 4G is expected to exceed the current 3G network, but the
key will have to see after the commercial price. While China Mobile 4G
network Declaration on how high rate, but I was in the People's Square,
whether on foot or in a moving vehicle test, there will be a few corners
no 4G network, which is only a question of my own discovery.
Here I can only say that network optimization is plc analog io module not achieved overnight, the majority of users are direct witnesses, let us speak with the facts!
Here I can only say that network optimization is plc analog io module not achieved overnight, the majority of users are direct witnesses, let us speak with the facts!
2015年3月2日星期一
output module plc, which has several outputs in the form of general
Common plc output module, which has several outputs in the form of
general PLC switch output interfaces commonly used by the output of the
switching device, there are three different types: output module plc is a
relay output, transistor output and bidirectional thyristor output,
output module plc. PLC relay output is to use the relay contacts and
coils internal plc sequence of events recording module circuitry
with an external load circuit is electrically isolated from the PLC.
Transistor output type PLC via opto-coupler transistor is turned off or
turned on allows to control an external load circuit, while PLC internal
circuit and transistor output circuit is electrically isolated. Relay
outputs can drive AC or DC loads, but the long response time, low
operating frequency, but the load capacity of the strongest; while the
response speed of the transistor output and bidirectional thyristor
output interface, high plc input module operating
frequency, but the former can only be used to drive DC load, which can
only be used for AC load. Digital output generally two types: type
transistors, relays sex. Analog output generally two kinds: voltage,
current type.
How to handle input module plc plc signal
PLC analog input module to analog ( continuous signal ) is converted
to digital ( discrete signal ) usually after : sampling and quantization
two processes. For example, "analog" is the distance from the PLC Programmable industrial controller plc
origin of moving objects , " sampling " is equivalent with a camera
shooting, at regular intervals on the " capture " a picture , as long as
a suitable interval , the picture is also through these intermittent
energy about the trajectory of the object. " Quantify " the process is
to put these photos in various locations of objects are classified into a
limited number of specified location , such as 1 meter , five meters ,
10 meters ..... , namely the continuous position data . " format " (
converted to CPU can recognize and handle data format ) , to facilitate
the next step of CPU processing . Siemens S7-300PLC for example , 0-20mA
input corresponds to 0-27648 , namely PLC internal " 1" represents
(20/27648) mA; corresponds to the input of PLC Power supply module plc 5mA, internal PLC is represented by 6912 .
After the analog to digital conversion , the PLC can be carried out in a variety of digital processing ( including math, logic operation ) , according to the practical application of specific processes identified . For example , determining a first analog input channels of digital value is greater than 6912 ( corresponding to 5mA), meet the conditions , the output of a switch or a digital computing . If necessary you can also go through the digital analog output module ( inverse process) an analog output .
After the analog to digital conversion , the PLC can be carried out in a variety of digital processing ( including math, logic operation ) , according to the practical application of specific processes identified . For example , determining a first analog input channels of digital value is greater than 6912 ( corresponding to 5mA), meet the conditions , the output of a switch or a digital computing . If necessary you can also go through the digital analog output module ( inverse process) an analog output .
2015年2月26日星期四
The role of output modules plc
Fire alarm, the alarm controller output module needs to start by the linkage of external control devices, such as ethernet module plc control valve, sending valve, fire shutter doors, fans, alarm, etc., and to accept the action device to answer.
output module plc connected to the bus loop controller can be installed in the vicinity of the control equipment can also be installed in the plc high-speed counting module inside the terminal module. Electronic writing code, you can live encoding. Ji-output control logic output module can be completed according to the project situation programming. When the controller receives the alarm signal to the detector, based on pre-programmed into the procedure, the controller via the bus output control signal to the interlocking modules, output modules linkage needs to start fire-fighting equipment; action after the device receives a reply signal.
output module plc connected to the bus loop controller can be installed in the vicinity of the control equipment can also be installed in the plc high-speed counting module inside the terminal module. Electronic writing code, you can live encoding. Ji-output control logic output module can be completed according to the project situation programming. When the controller receives the alarm signal to the detector, based on pre-programmed into the procedure, the controller via the bus output control signal to the interlocking modules, output modules linkage needs to start fire-fighting equipment; action after the device receives a reply signal.
2015年2月12日星期四
plc io module is divided into several modules by function
plc io module is divided into several modules by function
plc IO module is divided into several modules according to function, such as CPU modules, input modules, output modules, power modules, and so on. The module features a communication modules plc mainframe is more some kind of modules and therefore relatively more. This can also be said to be the trend. At present, some medium-sized machine, the module features also tend to single species also increases Township. If the same OMRON Corporation intelligent plc series PLC, H machine CPU unit to contain the power, and put the power ceded Ha machine, a separate power supply module.
plc IO module is divided into several modules according to function, such as CPU modules, input modules, output modules, power modules, and so on. The module features a communication modules plc mainframe is more some kind of modules and therefore relatively more. This can also be said to be the trend. At present, some medium-sized machine, the module features also tend to single species also increases Township. If the same OMRON Corporation intelligent plc series PLC, H machine CPU unit to contain the power, and put the power ceded Ha machine, a separate power supply module.
2015年2月3日星期二
Definition of the PLC
There are many definitions PLC. International Electrotechnical Commission (IEC) is the definition of the PLC: Programmable Logic Controller is a digital electronic computing operating programmable logic controller system, designed for applications in industrial environments. It uses a programmable memory, used in its internal storage to perform logical, sequential control, timing, counting and arithmetic operations such as operating instructions, and through digital and analog inputs and outputs, control types machinery or production processes. Programmable logic controller and related equipment, all with industrial control systems should be easy to form a whole, to expand the principles of the design of its functions.
The mid-1980s to the 1990s, is the fastest growing PLC period, the annual growth rate has been maintained at 30 to 40 percent. During this period, PLC capability in handling analog and digital computing power, man-machine interface capabilities and network capabilities have been greatly improved, PLC gradually entering the field of process control, in some applications in the field of process control to replace the dominant DCS systems.
PLC has the versatility, ease of use, wide adaptation, can be * high anti-jamming
capability, programming and simple. PLC in the industrial automation and control especially in order to control the position, in the foreseeable future, can not be replaced.
| plc power supply module |
2015年1月31日星期六
the role of module
Modular used to separate, organize and packaged software. Each module performs a specific sub-function, all the modules are assembled by some method, as a whole, complete system required functions.
plc moduleshas the following basic attributes: external characteristics of the interface, functions, logic, status, functional status and interface modules reflect the logic reflect its internal characteristics.
In the structure of the system, the modules are combined decomposition and replacement unit. Modularity is a complex system can be decomposed into ways to better manage modules. It can be set by different components of different functions, to decompose the problem into a plurality of small independent, interacting components, to deal with complex, large-scale software.
Run mode
1, the operating mode to work independently
Each module can work independently, even a single set of module failure does not affect the whole system work.
2. Start function classification
When each group of modules to reach full capacity the system will automatically activate another set of modules to ensure the system is always output to match actual demand and to ensure the efficient operation of each plc output module, but also save resources and improve efficiency.
plc moduleshas the following basic attributes: external characteristics of the interface, functions, logic, status, functional status and interface modules reflect the logic reflect its internal characteristics.
In the structure of the system, the modules are combined decomposition and replacement unit. Modularity is a complex system can be decomposed into ways to better manage modules. It can be set by different components of different functions, to decompose the problem into a plurality of small independent, interacting components, to deal with complex, large-scale software.
Run mode
1, the operating mode to work independently
Each module can work independently, even a single set of module failure does not affect the whole system work.
2. Start function classification
When each group of modules to reach full capacity the system will automatically activate another set of modules to ensure the system is always output to match actual demand and to ensure the efficient operation of each plc output module, but also save resources and improve efficiency.
2015年1月26日星期一
What is the role of PLC input and output modules are used in the fire?
Now the temperature sensitive smoke into intelligent coding and non-coding, coding can directly intelligent feedback signal to the host address (host needs to know where the fire occurred), the non-coding the feedback address signal can not be directly connected to an input module common practice module are capable of encoding such a host can receive address signals. For example now in the basement of temperature-sensitive non-coding common sense as long as the temperature of each partition to an input module, the host just know which partition is on the line of fire. Do not need to locate the point. The use of smoke on the ground pointing to the different needs of the specific location. Then the need for a lot of non-coding module, and therefore the need for direct feedback encoder type flue gas temperature sensation address. The same is now also have coding manual alarm button code hydrant pump start button coded telephone Some devices can not be directly input and output signals such as pressure switch damper valve flow indicator signals, etc. These can only have a current output is not coded signal. Then need to use the input plc modules, the device output power to the plc input output modules signal to the host. Output module is required when the host device host only direct linkage control output code modules, and then output power required to drive the linkage equipment.
2015年1月22日星期四
What is the fire in a single-input \ single output modules?
This plc module is used for a variety of live action and a motion signal output passive devices such as: exhaust valves, send valve, dampers and other access to the control bus.
This module uses electronic encoder to encode in the small plc has a pair of normally open, normally closed contacts. Module has a 24V DC voltage output for the relay contacts connected to the active output to meet the different needs of the scene. Another module also has a switching signal input for the switch contacts and the field devices connected to the field devices to confirm whether the operation. It should be noted that the module should not be directly connected to AC control loop contact, to prevent damage to the module strong AC interference signal or control equipment.
This module uses electronic encoder to encode in the small plc has a pair of normally open, normally closed contacts. Module has a 24V DC voltage output for the relay contacts connected to the active output to meet the different needs of the scene. Another module also has a switching signal input for the switch contacts and the field devices connected to the field devices to confirm whether the operation. It should be noted that the module should not be directly connected to AC control loop contact, to prevent damage to the module strong AC interference signal or control equipment.
2015年1月17日星期六
What is the role of input and output modules are used in the fire?
Now the temperature sensitive smoke into intelligent coding and non-coding, coding can directly intelligent feedback signal to the host address (host needs to know where the fire occurred), the non-coding the feedback address signal can not be directly connected to an input module common practice module are capable of encoding such a host can receive address signals. For example now in the basement of temperature-sensitive non-coding common sense as long as the temperature of each partition to an plc input module, the host just know which partition is on the line of fire. Do not need to locate the point. The use of smoke on the ground pointing to the different needs of the specific location. Then the need for a lot of non-coding plc modules, and therefore the need for direct feedback encoder type flue gas temperature sensation address. The same is now also have coding manual alarm button code hydrant pump start button coded telephone Some devices can not be directly input and output signals such as pressure switch damper valve flow indicator signals, etc. These can only have a current output is not coded signal. Then need to use the input module, the device output power to the input module module output signal to the host. Output module is required when the host device host only direct linkage control output code modules, and then output power required to drive the linkage equipment.
2014年12月29日星期一
Technical features PLC output module
(1) Operating voltage:
Bus voltage: 24V bus allowable range: 16V ~ 28V
Power supply voltage: DC24V allowable range: DC20V ~ DC28V
(2) Working current:
Bus monitor current ≤1mA bus starting current ≤2mA
Power supply monitor current ≤5mA starting current ≤20mA
(3) Output Capacity: Each plc module can carry loads up to 60W
(4) Operation indicator: red (action lit)
(5) inspection indicator: green (when logging flashing)
(6) Encoding: electronic encoding, take a bus coding point, coding range can be set between 1 to 242
(7) Wire: Two bus connection to the programmable logic controller signals second bus and power; two speaker wire and bus-type fire radio input line
(8) Use of the environment:
Temperature: -10 ℃ ~ + 55 ℃
Relative humidity ≤95%, non-condensing
(9) Dimensions: 64mm × 64mm × 23mm (excluding transparent cover)
(10) of the housing materials and colors: ABS, beige
(11) Weight: about 75g (including transparent cover)
(12) implementation of the standards: GB 16806-2006
Bus voltage: 24V bus allowable range: 16V ~ 28V
Power supply voltage: DC24V allowable range: DC20V ~ DC28V
(2) Working current:
Bus monitor current ≤1mA bus starting current ≤2mA
Power supply monitor current ≤5mA starting current ≤20mA
(3) Output Capacity: Each plc module can carry loads up to 60W
(4) Operation indicator: red (action lit)
(5) inspection indicator: green (when logging flashing)
(6) Encoding: electronic encoding, take a bus coding point, coding range can be set between 1 to 242
(7) Wire: Two bus connection to the programmable logic controller signals second bus and power; two speaker wire and bus-type fire radio input line
(8) Use of the environment:
Temperature: -10 ℃ ~ + 55 ℃
Relative humidity ≤95%, non-condensing
(9) Dimensions: 64mm × 64mm × 23mm (excluding transparent cover)
(10) of the housing materials and colors: ABS, beige
(11) Weight: about 75g (including transparent cover)
(12) implementation of the standards: GB 16806-2006
2014年12月12日星期五
Digital input and output modules each play what role in the PLC control system
plc analog input module is an external control signal or field detection signal processing module to the PLC CPU, an external signal is generally button, proximity switches, limit switches, PLC output module is based on the signal processing logic and internal plc programmable logic controller taken into the , the results of treatment before, switch output signal is output by the high and low output module, to drive external relays, contactors, lights, solenoid valves and other components, thereby enabling the external device corresponding action
2014年8月12日星期二
input module, also known as the control module
input module, also known as the control module, when the output signal can control requirements, or to provide a switching signal to the controlled device movements, and can receive feedback signal device to the host to report to the fire alarm system is an important linkage part of the plc input module and output modules on the market can provide a pair of passive normally open / normally closed contacts for controlling the controlled device, some manufacturers of analog input module can be set via the parameter set corresponding to the active output there are pairs of input and output modules, multiple input and output modules, and so on.
订阅:
博文 (Atom)